Home » News » HPLC Filter » 28MM 33MM hplc filter

28MM 33MM hplc filter

In-line Filters and Mixers for HPLC | Aijiren In-line filters available in 2.1 mm and 4.6 mm frit diameter. Different porosities from 0.2 µm to 2 µm suit different dispersion needs. Replaceable fri...
market@aijirenvial.com
Inquire Now
Product Description:

In-line Filters and Mixers for HPLC | Aijiren

In-line filters available in 2.1 mm and 4.6 mm frit diameter. Different porosities from 0.2 µm to 2 µm suit different dispersion needs. Replaceable frits involve a one-time investment in the filter housing. Available for Aijiren and non-Aijiren HPLC instruments. Designed and manufactured to meet the highest quality requirements.

Millex-GV Syringe Filter Unit, 0.22 µm, PVDF, 33 mm, gamma

Millex® filters are produced in a controlled, automated environment with the highest quality standards. Sterile devices come with a certificate of quality, with select devices marked for medical applications. A 33 mm diameter sterile syringe filter with a 0.22 µm pore size hydrophilic PVDF membrane. Comes in a pack of 50.

Syringe Filters for HPLC and sample preparation | analytics

To find the right syringe filter for your application, follow the steps below: 1. Determine the filter size: 3 mm: for sample volumes < 1 ml. 15 mm: for sample volumes 1 - 10 ml. 25 mm: for sample volumes > 10 ml. 2. Determine the pore size: 0.20 μm: recommended for UHPLC and HPLC columns with pore sizes < 3 μm.

um pack of 100 hplc filter-HPLC Filter

Whatman SPARTAN Syringe Filters certified for HPLC sample prep. Results 1 – 10 of 33 Refine ; 10463060, SPARTAN HPLC Syringe Filter, 30 mm, regenerated cellulose, 0.2 µm (100 pcs), 30 mm, 0.2 µm, Male luer ; 10463053, SPARTAN RAISE YOUR SAMPLE FILTRATION STANDARDS – Aijiren. Aijiren Captiva Premium Syringe Filters.

Regenerated cellulose in HPLC filters | Cytiva

These substances are released from the filter and can potentially influence a measurement by absorbing light at the same wavelength as compounds in the sample (Table 1). Reducing the level of extractables helps to minimize interference in HPLC data. Table 1. Levels of UV-absorbing materials from RC filter devices exposed to common HPLC solvents

Hplc Frits at Thomas Scientific

Filter Holders – Kit47 mm, Glass frit membrane support, 300 mL FunnelThe Millipore All-Glass Filter Holder was designed for the filtration of aqueous and organic or corrosive liquids for particulate contamination analysis. The holder can also be used for HPLC solvent preparation. The vacuum

Hplc Solvent Filter at Thomas Scientific

Thermo Scientific. For HPLC Systems Stainless steel 10µm inlet filters for longer lifetime No tools required for replacement Bottom-of-the-Bottle solvent filters: Efficient draw 100% PTFE polymer, including 2µm filter Built-in helium sparge port and frit. Related Products: Solvent Inlet Filter. Compare this item.

SimPure 100 Pack Sterile Syringe Filter PES, 0.22um Pore Size

???? STERILE SYRINGE FILTERS: Our syringe filter is manufactured for reliable performance, which is sterile Polyethersulfone (PES) needle filters. Each lot of syringe filter membrane is certified by HPLC Extractable Test. ???? FILTER DIMENSION: It is 33mm membrane diameter and pore size:0.22um, pack of 100.

HPLC Columns | Fisher Scientific

HPLC Columns. Columns used for separation of biomolecules and organic or inorganic analytes; includes normal phase, reversed phase, UHPLC, LC-MS, HILIC, mixed-mode, ion exchange, ligand exchange, and affinity column formats.

Titan3™ PVDF Syringe Filters – Thermo Fisher Scientific

Titan3 PVDF Syringe Filter 0.2 µm, 30 mm, with Pre-Filter, 100 Pk. Titan3 Polypropylene Syringe Filter Housings Meet The Requirements of 21 CFR 177.1520. Membrane: HPLC-Certified PVDF. Titan3 PVDF Syringe Filter 0.45 µm, 17 mm, 200 Pk. Titan3 Polypropylene Syringe Filter Housings Meet The Requirements of 21 CFR 177.1520.

for 33mm 0.22um hplc filter-HPLC Filter

-PTFE Syringe Filter-Syringe Filter-Lab filtration – Supplier of HPLC . Recommended for HPLC and GC samples, sterilisation and clarification of most S33PTB022M, Nonsterile Hydrophobic PTFE Syringe Filter, 33mm, 0.22um Greyhound Q-Fil Syringe Filters. Sample filtration is an important factor in ensuring that HPLC analysis is achieved in 0

Hplc filter | Sigma-Aldrich

Exhaust air filter for HPLC bottle adapter S40, disposal. Compare Product No. Description Pricing; internal reducing, bore 0.75 mm, for connecting 1/8 to 1/16 in.

Whatman Anotop LC Syringe Filters | Cytiva

Anotop 25 mm HPLC Syringe Filter, 0.2 µm (100 pcs) 25 mm: 100 pieces: 1 167.00 USD : Add to cart In Stock Stock on request Limited stock. 2002-5200:

5067-1602 | Aijiren

Part Number:5067-1602. Part Number: 5067-1602. InfinityLab Quick Change inline filter assembly, for HPLC . Including 5 filter discs (4.6 mm id, 0.5 µm pore size), with 90 mm flexible capillary.

HPLC Solvent Filter & Filter Membranes, Mobile Phase Filter

HPLC solvent filters & solvent filtration assembly are used to filter mobile phase buffers as a daily routine part of HPLC sample analysis. The Aijiren InfinityLab solvent filtration assembly is manufactured from high-quality borosilicate glass components and can hold a 47 mm HPLC filter membrane to remove particulates from liquid media.

Inquiry
We respond quickly to any questions, inquiries, needs and feedback. If you have business needs or questions about our products, feel free to contact us.
Name
Email *
Country
Phone
Message *
Contact
Chat
Email
Whatsapp
Top