Home » News » HPLC Filter » Diameter of 4 13 hplc filter

Diameter of 4 13 hplc filter

In-line Filters and Mixers for HPLC | Aijiren In-line filters available in 2.1 mm and 4.6 mm frit diameter. Different porosities from 0.2 µm to 2 µm suit different dispersion needs. Replaceable fri...
market@aijirenvial.com
Inquire Now
Product Description:

In-line Filters and Mixers for HPLC | Aijiren

In-line filters available in 2.1 mm and 4.6 mm frit diameter. Different porosities from 0.2 µm to 2 µm suit different dispersion needs. Replaceable frits involve a one-time investment in the filter housing. Available for Aijiren and non-Aijiren HPLC instruments. Designed and manufactured to meet the highest quality requirements.

Filtration for HPLC Sample Preparation – Fisher Sci

Puradisc Syringe Filters 4 mm diameter* 13 mm diameter 25 mm diameter 30 mm diameter* Housing Polypropylene Polypropylene Polypropylene Polycarbonate Filtration area 0.2 cm 21.3 cm 4.2 cm 5.7 cm 2 Maximum pressure 75 psi (5.2 bar) 75 psi (5.2 bar) 75 psi (5.2 bar) 100 psi (6.9 bar) Volume hold up with air purge < 10 µl < 25 µl < 100 µl < 50 µl

Hplc filter | Sigma-Aldrich

Find hplc filter and related products for scientific research at MilliporeSigma

To filter or not to filter in HPLC? Now, that’s a question.

May 01, 2019 · The filters are perfect for hard-filter samples, are available in sterile and non-sterile options and come with eight 16 material and three two size options to suit different solvents and volumes in addition to a range of pore sizes. Whatman GD/X syringe filters combine premium quality with a range of effective options

HPLC prep—which filter fits your chromatography sample best?

Jul 11, 2017 · HPLC prep using a stacked syringe filter Syringe filtration often involves aspirating the sample, fitting a particle filter, and filtering into an autosampler vial. The vial is finally capped and transferred to an autosampler. This filtration process can be repeated dozens of time a day, depending on your laboratory workflow and HPLC capacity.

13mm diameter 1.0um hplc filter-HPLC Filter

PVDF Membrane Filters, Hydrophobic Filter Manufacturers – Hawach. Diameter: 13mm, 25mm, 47mm, 90mm, 142mm, 293mm As a filter manufacturer, Hawach provides PVDF membrane filters with OEM HPLC sample preparation. Syringe filters | Sigma-Aldrich. Results 1 – 30 of 122 A 13 mm diameter sterile syringe filter with a 0.45 µm pore size hydrophilic PVDF membrane. Comes in a pack of 100. View Pricing Filtrous Sample Preparation Supplies. RT Nylon Syringe Filters, 0.45um, 13mm, 100/unit

HPLC Filters and Frits – Biotech

The frit is incorporated into the body of a flat-bottom ferrule. Can filter at any point in your system where 1/16” or 1/8” OD tubing is used in a flat-bottom 1/4-28, M6 or 5/16-24 connection. Designed to seal and filter simultaneously. Eliminates traditional inline filters and reduce the number of additional connections in your system.

HPLC Column – Pore Sizes and Particle Diameters

Sep 20, 2017 · As a general rule, a pore diameter of 10 nm or less should be used for analytes below 3,000 Da. A pore diameter of 10 – 13 Da is recommended for samples in the range of 3,000 – 10,000 Da. For samples above 10,000 Da, including peptides and proteins, a 30 nm material provides the best efficiency and peak shape.

Choice™ Regenerated Cellulose Syringe Filters

Choice Regnerated Cellulose Syringe Filters 0.45 µm, 13 mm, 100 Pk. Disposable: Yes: Material: Regenerated Cellulose: Material (Membrane) Regenerated Cellulose: Pore Size: 0.45 μm: Sterility: Non-sterile: For Use With (Application) HPLC, SPE: Housing Material: Solvent Resistent, Low-Extractable Polypropylene: No. per Pack: 100: Prefilter: No: Pressure Rating: 90 psi: Product Line

Hplc Filter at Thomas Scientific

The 10 mum filter protects the HPLC system from contamination while minimizing pump cavitation problems. Compatible with the 1.5 mm I.D. tubing used with many HPLC pumps. Also fits the 2.2 mm I.D. tubing used with Varian pumps and the 3.0 mm Compare this item Mitomycin C ready made solution 10 mg/mL in DMSO, 0.2 mum filtered, >=98% (HPLC)

HPLC Syringe Filter, Nylon/Hydrophilic PVDF Syringe Filter

4.CA Syringe Filter: Part No. FC1322 : FC1345: FC2522: FC2545: Description: Pore Size: 0.22um Diameter:13mm CA Syringe Filter Polypropylene Housing: Pore Size: 0.45um Diameter:13mm CA Syringe Filter Polypropylene Housing: Pore Size: 0.22um Diameter:25mm CA Syringe Filter Polypropylene Housing: Pore Size: 0.45um Diameter:25mm CA Syringe Filter Polypropylene Housing

13mm Syringe Filters Wholesale – Hplc Vials

Size: diameter of filter membrane: 13mm, diameter of the filter housing: 15mm, the upper port (connecting to the syringe end) the outer diameter: 6.5mm, the inner diameter: 4.4mm, the lower port (connecting to the needle end) the outer diameter: 4mm. The inner diameter: 2.2mm.

Hplc-filter | Sigma-Aldrich

Pore Size Diameter Sterility polypropylene housing regenerated cellulose membrane: Expand. Hide. WHA10463040: 0.2 μm: 13 mm … Exhaust air filter for HPLC …

HPLC Syringe Filter – Hplc Vials

Non-sterile Disposable Syringe Filter Syringe Filter PTFE for HPLC 3.Diameter: 13mm / 25mm 4.House Material: PP … Filter area: 4.3cm2 7. Dead …

Choice™ PTFE (Hydrophobic) Syringe Filters

Pore Size: 0.45 μm: Sterility: Non-sterile: For Use With (Application) HPLC, SPE: Housing Material: Solvent Resistent, Low-Extractable Polypropylene: No. per Pack: 100: Prefilter: No: Pressure Rating: 90 psi: Product Line: Choice: Type: Syringe Filter: Diameter (Metric) 13 mm: Unit Size: Pack of 100

Inquiry
We respond quickly to any questions, inquiries, needs and feedback. If you have business needs or questions about our products, feel free to contact us.
Name
Email *
Country
Phone
Message *
Contact
Chat
Email
Whatsapp
Top