Syringe Filters – Sigma-Aldrich
Whatman ® Spartan ® syringe filters provide reproducible filtration of organic and aqueous solutions for high performance and ultra-high performance liquid chromatography (HPLC and UHPLC) sample preparation. For batch-to-batch consistency, these filters are tested and certified for the absence of UV-absorbing substances at wavelengths of 210 and 254 nm with water, methanol, and acetonitrile.
VWR® Syringe Filters | VWR
VWR® Syringe Filters Supplier: VWR, part of Avantor Polypropylene, nylon, and PTFE membranes are ideal for sample preparation and small volume chemical filtration. Ideal for sterile filtration Manufacturing process certified to ISO 9001 Biosafe according to Class VI plastics tests
Syringe Filter, 4mm 0.22um Nylon Yellow Luer Lock 100-pk
Cellulose Acetate, Nylon, PES, PVDF—hydrophilic applications PTFE—hydrophobic applications Syringe filters are for laboratory use only. Color: yellow Diameter: 4 mm Material: Nylon Porosity: 0.22 µm Product Name: Syringe Filter Product Type: Syringe Filter Units: 100-pk. Price: $149.00 In stock Quantity:
Millex® Syringe Filters – Sigma-Aldrich
Millex-FG, 0.20 µm, hydrophobic PTFE, 50 mm, A 50 mm diameter non-sterile syringe filter with a 0.2 µm pore size hydrophobic PTFE membrane. Comes in a pack of 10. Expand SLHN033 Millex Syringe Filter, Nylon, Non-sterile, 0.45 µm pore size, 33 mm diameter, Millex-HN Nylon membrane, hydrophilic Expand SLGV033N
0.22um Sterile Nylon for hplc filter-HPLC Filter
0.22 Nylon Filter at Thomas Scientific. amounts of aqueous extractables. Nylon is compatible with a broad range of aqueous and alcoholic solutions and solvents that are frequently used in HPLC. No 0.22 Micron Syringe Filter – alwsci. Sterile Nylon 25mm 0.22 micron syringe filter. 100% integrity tested. Ideal for sterile filtration.Used for lab use and sensitivity test.
0.22 Nylon Filter at Thomas Scientific
Purple Nylon Syringe Filters, 0.22 µm PerkinElmer for aqueous (non-acidic) or organic sample preparation and HPLC, GC or dissolution sample analysis. With its excellent flow characteristics, very low extractable levels and mechanical stability, Nylon offers the best combination of physical parameters to meet the most stringent analytical needs.
How to Select a Syringe Filter and How to Use it? (2020 Guide)
Feb 17, 2020 · Step 2: Attach a syringe filter to the Syringe. Open the syringe filter package so that you can later pick the filter up easily, especially for individually packed sterile syringe filters. a. For sample volume < 10 mL. Draw a small amount of air (about 1 mL) into the syringe before loading the sample solution.
47 mm, 0.45 µm, HPLC Nylaflo™ (Nylon) Membrane Disc Filter
HPLC Mobile Phase Filtration Membranes – 0.45 µm, Nylaflo (Nylon) membrane (100/pkg) Product ID: 66608 Need this product with different specifications. Min Order Qty: 1. $ 196.02 / PAC.
Chemical Analysis, Life Sciences, and Diagnostics | Aijiren
Chemical Analysis, Life Sciences, and Diagnostics | Aijiren
0.22 Filter at Thomas Scientific
Syringe Filter, Nylon, 0.22µm, 30mm Diameter Denville around it. Denville Syringe Filters are easy to use. They may be used with any luer-lock syringe and are color-coded for easy recognition. The 30mm syringe filters can filter up to 100mL of sample with a retention volume of less than 100µL.
Captiva Syringe Filters | HPLC | Aijiren
Syringe Filters. Captiva syringe filters offer the industry’s highest flow rates and loading capacities. Using Captiva syringe filters also significantly extends column lifetime. Choose from a variety of membrane types and pore sizes to prepare small-volume samples for High-Performance Liquid Chromatography (HPLC) and ion chromatography.
Syringe Filters – Pall Corporation
For example, syringe filters containing 0.45 μm are typically used for HPLC sample preparation and 0.2 μm is used for UHPLC. In life science applications 0.1 and 0.2 µm pore sizes provide sterilization of buffers, culture media, and additives. Larger 0.45, 0.8, 1.2 and 5 µm membrane pore sizes can be used for prefiltration and/or clarification.
Corning Filtration Guide
biological fluids and gases is usually done with 0.2 or 0.22 µm pore filter membranes. Clarification and prefiltration of solutions and solvents is best accomplished with 0.45 µm or larger filter membranes. Prefiltration to improve filter performance can also be accomplished by the use of glass fiber prefilters that can be purchased separately.
Syringe Filter Nylon for Laboratory – Hplc Vials
3. Two types in pore size: 0.22um and 0.45um. 4. Three types in filter size: 13mm, 25mm, 33mm aviliable. Applications • Filtration of aqueous and organic mobile phases • Vacuum degassing • Filtration of tissue culture media, microbiological media, buffers, and solutions • HPLC aqueous sample preparation • Biological sample preparation
Nylon filter membranes pore size 0.22 μm, diam. 47 mm, pack
Nylon filters are naturally hydrophilic and no wetting agents are used in manufacture. With an extractable level <0.0015 mg/cm 2, they are ideal for HPLC solvent and sample preparation. Because of high non-specific binding, they are not recommended for protein solutions.