Syringe Filters for Sterile Filtration | Minisart® | Sartorius
Sterile filtration, clarification, and particle removal. Minisart ® NML Syringe Filters provide the optimal method for clarification and sterilization of liquids, robustly removing bacteria and particles, without any impact on product quality or loss of target molecule. Superior filter areas up to 6.2 cm 2. 0.1µm to 5µm pore sizes.
At Least 11 Things You Didn’t Know about – Biocompare
Jun 11, 2018 · Why does filter membrane pore size matter? You may have filter devices in your lab marked with specifications like 0.1, 0.22, or 0.45 µm. These pore size designations contribute to the filter’s rating, or what particle size may pass through the filter under laboratory conditions. The scale below helps to put macromolecules, common particles
Nylon Membrane Filters 0.45 at Thomas Scientific
Versatile Laboratory Membrane Filter Excellent chemical compatibility with esters, bases, and alcohols Naturally hydrophilic Available in 0.2 and 0.45 µm pore sizes, in diameters ranging from 13 to 142 mm HPLC certified.
Ultrafree®-MC and -CL Centrifugal Filter Units – Sample
Ultrafree ® -MC (0.5 mL) and Ultrafree ® -CL (2 mL) centrifugal devices are single-use, disposable filters used for removing particulates from aqueous biological solutions. These devices are available in two processing volumes with a range of microporous membranes (from 0.1 to 5.0 µm) for fast filtration and highly reproducible performance.
Corning Filtration Guide
Application Pore Size (µm) Membrane Availability Mycoplasma Removal 0.1 PES Sterilization and Ultracleaning 0.20 to 0.22 All membranes except PTFE of Aqueous Solutions Ultracleaning of Solvents (HPLC) 0.20 to 0.22 RC, nylon, and PTFE Clarification of Aqueous Solutions 0.45 All membranes except PTFE
47 mm, 0.45 µm, HPLC Nylaflo™ (Nylon) Membrane Disc Filter
Filter Media. Hydrophilic nylon; Pore Size. 0.2 and 0.45 µm; Typical Thickness. 127 µm (5 mils) Typical Water Flow RatemL/min/cm 2 at 0.7 bar (70 kPa, 10 psi) 0.2 µm: 12; 0.45 µm: 16; Maximum Operating Temperature – Water. 100 °C (212 °F) Minimum Bubble Point – Water. 0.2 µm: 3.4 bar (340 kPa, 49 psi) 0.45 µm: 2.6 bar (260 kPa, 37 psi)
HPLC Syringe Filter, Nylon/Hydrophilic PVDF Syringe Filter
Pore Size: 0.22um Diameter:25mm Nylon Syringe Filter Polypropylene Housing: Pore Size: 0.45um Diameter:25mm Nylon Syringe Filter Polypropylene Housing: 6.PP Syringe Filter : Part No. FP1322: FP1345: FP2522: FP2545 : Description: Pore Size: 0.22um Diameter:13mm PP Syringe Filter Polypropylene Housing: Pore Size: 0.45um Diameter:13mm PP Syringe
Syringe Filters – Pall Corporation
Pore size ratings are usually stated in Micrometers (μm). Syringe filters with different pore size ratings are suitable for different applications. For example, syringe filters containing 0.45 μm are typically used for HPLC sample preparation and 0.2 μm is used for UHPLC.
Durapore® Membrane Filter, 0.45 µm | HVLP04700 – EMD Millipore
HVLP04700. Trade Name. Durapore ®. Description. Durapore® Membrane Filter, 0.45 µm. Background Information. Durapore® membranes provide high flow rates and throughput, low extractables and broad chemical compatibility. Hydrophlic Durapore® membrane binds far less protein than nylon, nitrocellulose, or PTFE membranes. Features & Benefits.
pore size 0.22um 0.45um 0.1um Nylon hplc syringe filters
Feature: filter diameter: 13mm, pore size: 0.22um, membrane material: PVDF , hydrophobic property . Syringe filters are made of inert plastic house, membrane, and luer lock fit. It is used with disposal syringes or filtration device with luer fit. Syringe filters are often one-time . size 0.22um 0.45um 0.1um Nylon 0.45um hplc syringe filters
The Differences Between Nylon Membrane Filters and MCE
Apr 23, 2020 · The principle of pore size selection is the same as the mixed fiber membrane, that is, the removal of particles using nominal pore size um, sterilization using nominal pore size 0.65 um, 0.45um, 0.3um, 0.22um, 0.1um, diameter:100 mm, 150mm, 200mm, 300mm, 400mm.
Syringe Filter Nylon for Laboratory – Hplc Vials
1. Nylon syringe filter with colored ring, with printing. 2. Membranes in analytical and research applications. 3. Two types in pore size: 0.22um and 0.45um. 4. Three types in filter size: 13mm, 25mm, 33mm aviliable. Applications • Filtration of aqueous and organic mobile phases • Vacuum degassing
Millipore® Filter Membranes
Due to this difference, nylon net filters possess a uniform, large pore structure (similar to a mesh), a pore size ≥5.0 μm, and a reduced thickness in comparison to nylon membrane filters. Isopore™ polycarbonate membrane filters offer well-defined pores and a smooth transparent surface ideal for use with optical or electron microscopy.
How to Select a Syringe Filter and How to Use it? (2020 Guide)
Feb 17, 2020 · Which Pore Sizes to Select? 0.22um or 0.45um? The most commonly used syringe filter pore sizes are 0.2/0.22 um and 0.45 um syringe filters, for research and medical applications. The pore size to be used is usually determined by the particle size to be eliminated.
Nylon 0.45 Filter at Thomas Scientific
Thermo Scientific Nalgene. filters remove all bacteria 0.45 and 0.8 micron filters for particle removal and fluid clarification 90 mm diameter filters provide large surface area for serum and other hard-to-filter solutions Ergonomic design 1 1/2 turn screw cap, tapered sides and “grips” make the filter ….